Home > Products > Signal and Monitoring >
eDAQ >
Contactless Conductivity Systems
eDAQ supplies several products for ion chromatography (IC) capillary electrophoresis (CE), and microfluidic channel electrophoresis using Capacitively Coupled Contactless Conductivity Detection
| |
|
|

|
C4D Amp
The C4D Amp is a high sensitivity capacitively-coupled
contactless conductivity detector (C4D)
for capilliary electrophoresis (CE) and
ion chromatography (IC) systems, using PowerChrom
system, or e-corder data acquistion systems.
It is supplied with a suitable headstage,
usually the ET120 C4D Head (for CE or IC),
or optionally the ET121 C4D Microfluidic
Platform for use with microfluidic channel
chips. Excitation frequency and amplitude
can be optimised by the user for maximum
signal sensitivity. Suitable for use with
e-corder or PowerChrom systems for data
collection.
|
|
C4D Detector
This unit is a high sensitivity capacitively-coupled
contactless conductivity detector (C4D) for
capilliary electrophoresis (CE) and ion chromatography
(IC) systems. It is supplied with a suitable
headstage, usually ET120 C4D Head (CE or IC),
or optionally ET121 C4D Microfluidic Platform
for use with microfluidic channel chips.
Excitation frequency and amplitude can
be optimised by the user for maximum signal
sensitivity. Both digital (RS232) and analog
signals (±3 V max) are provided for use
use with many types of data acquisition
systems.
|
|
C4D Headstage for Capillary Electrophoresis
The ET120 C4D Headstage is designed for
capillary electrophoresis (CE) or ion chromatography
(IC). It must be connected to either the
C4D Amp or C4D Detector.
The C4D Head contains a pair of cylindrical
electrodes which act as the transmitter
and receiver for an AC waveform signal provided
by the C4D Amp or C4D Detector. The capillary
tubing passes through the C4D headstage
and the pair of electrodes.
|
|
C4D Microfluidic Platform
This platform
is designed for contactless conductivity
detection on a microfluidic chip (lab-on-a-chip).
It must be connected to either the C4D Amp
or C4D Detector.
The platform has a pair of flat electrodes
which act as the transmitter and receiver
for the AC waveform signal provided by the
C4D Amp or C4D Detector. The microfluidic
channel is positioned so as to pass across
the pair of electrodes. The base of the
microfluidic chip should be less than 200
µm thick, so that the electrodes are as
close to the sample channel as possible.
.
|
|
C4D System Bundle
The ER283
C4D System Bundle includes the ER280 PowerChrom
system and EA120 C4D Amp.
This system comes complete with C4D Amp,
software, data recording unit and a choice
of the headstage for capillary electrophoresis
or the platform for microchip electrophoresis.
Bundle components:
- EA120 C4D Amp (includes choice
of headstage or platform)
- ER280 PowerChrom System (includes PowerChrom
software)
|
For more information regarding the products above, CONTACT US
To select another eDAQ Product, CLICK HERE
To go back to Signal and Monitoring page, CLICK HERE
|