ORTEC solutions for gamma spectroscopy, with High Purity Germanium or Sodium Iodide detectors cover a wide range. Applications include environmental monitoring, environmental and radiochemistry counting rooms, in situ Measurements, on-line process monitoring, safeguards, non-destructive assay, water monitoring, homeland Security
and whole body counting.
Ortec detectors employ the transplantable PopTop capsule configuration. If you choose the PopTop, you will be able, inexpensively, to select more than one cryostat configuration, either now or later.
Non-PopTop configurations are also available for demanding applications.
Below are some of the HPGe and NaI detectors from the ORTEC range used for Gamma Spectroscopy. For an overview on choosing the right photon detector, click here. For detailed specifications of the detectors below, please Contact Us.
| |
|
|
GEM High-Purity Germanium (HPGe) Coaxial Detectors (in PopTop Capsule)
GEM Series HPGe detectors are manufactured with ORTEC’s own HPGe
and represent the state of the art in "conventional",
i.e., outer contact Li diffusion and inner contact ion-implanted HPGe coaxial
detectors. Because of the superior quality of ORTEC’s HPGe
material, GEM detectors feature the best available energy resolution,
peak-to-Compton ratios, and peak symmetry ratios at 1.33 MeV. Note
that energy resolution and symmetry ratios are warranted to two
decimal places.
- Large stocklist at all times
- Efficiencies to 150%, higher on request
- New "Application-Tuned" PROFILE Series available
- PopTop flexibility
- Excellent energy resolution and peak symmetry
- Automatic high-voltage shutdown protects preamplifier input FET
- Indicator warns of excessive counting rate
- PLUS preamplifier option for ultra-high-rate applications
|
|
PROFILE Series
GEM HPGe Coaxial Detectors
PROFILE GEM detectors are a first in germanium detectors; a range of detectors from which you can choose the best solution for your application from specified crystal dimensions. They are available in 2 series of endcap sizes. Nominal relative efficiency specifications are provided in order to help relate relative efficiency to terms of crystal dimensions. The resolution is measured according to the IEEE standard.
Avalilable in F series which employ "over-square" (diameter > length) coaxial structures, FX series (with an ULTRA-thin Entrance Window) or M series optimized for use with Marinelli Beakers.
|
|
GAMMA-X HPGe Coaxial Detectors (in PopTop Capsule or Streamline Cryostats)
The GAMMA-X detector is a coaxial germanium (Ge) detector with an
ultra-thin entrance window. While most coaxial detectors have entrance windows from 500-
to 1000-µm thick, the entrance window of the GAMMA-X detector is a 0.3-µm-thick,
ion-implanted contact. Ion implantation results in a totally stable contact which will not
deteriorate with repeated cycling.
For Compton-suppressed gamma spectroscopy, for measurements involving spectroscopy over the widest energy range, and in any situation where neutron damage is likely.
- Efficiencies to over 100%
- PopTop flexibility
- Spectroscopy from 3 keV to 10 MeV
- ULTRA thin, ultra stable boron ion implanted outer contact
- High resistance to neutron damage
- Excellent timing characteristics
- Be window supplied with protective cover; Al or carbon fiber window option available at no additional charge
- High-rate indicator
- PLUS preamplifier option for ultra-high-rate applications
- Automatic high-voltage shutdown protects preamplifier input FET
|

Dimensional Drawing of 51-mm-Diameter
LO-AX Detector Element
|
LO-AX™ Low-Energy Photon Detector
The LO-AX is a large active area, "short" coaxial detector which supplies the best possible energy resolution for the energy range from 3 to 400 keV.
A typical application for the LO-AX is in vivo quantitative actinide monitoring. This measurement, frequently performed in the past using phoswich scintillation counters, is now routinely performed using a LO-AX, usually in a low-background cryostat.
The LO-AX provides optimum peak-to-background ratio from 10 to 400 keV on large-area samples. It is also ideal for in vivo actinide monitoring using L x rays.
- Large active area
- 36-, 51-, 60-, and 70-mm diameter available
- Ideal for in vivo actinide monitoring
- Excellent for uranium monitoring
- PopTop flexibility
- ULTRA-thin rugged Ion-implanted pointer contact sensitive at front and sides
|
|
SMART-1 Detector
ORTEC’s unique SMART-1 detector interface module is a new technology for the
preamplifier and electronics interface. SMART-1 detectors contain a microprocessor that
monitors the state of health of a detector at all times. Crystal temperature, preamplifier
power (±12 and ±24), high voltage level and overload status are all monitored
periodically while data is being acquired. If any single parameter fails, a latched bit is
set. At the end of the measurement, SMART-1 enabled electronics (digiDART for instance)
poll the state-of-health bit and if it is latched, the operator is warned that a parameter
had exceeded limits during some part of the measurement. This feature ensures that the
data acquired is of the highest possible integrity.
|
|
905 Series
NaI(Tl) Scintillation Detectors
The high Z of iodine in NaI(Tl) crystals result in high efficiency for gamma-ray detection. Resolution for a
3-inch diameter by 3-inch length crystal is typically about 7% for 137Cs and slightly worse for larger sizes. The
light decay time constant for a NaI(Tl) crystal is about 0.23 ms. Typical charge-sensitive preamplifiers
translate this into an output voltage pulse with a rise-time of about 0.5 ms. Fast coincidence measurements
cannot achieve the very short resolving times that are possible for plastic scintillators, especially at low
gamma-ray energies.
The Model 905 Series offers various sizes of Nal(TI) detectors.
905-1 (1” x 1”): 0.17 @0.5 MeV and 0.09 @2.0 MeV
905-3 (2” x 2”): 0.75 @0.5 MeV and 0.45 @2.0 MeV
905-4 (3” x 3”): 2.00 @0.5 MeV and 1.30 @2.0 MeV
|
For more information regarding the products above, CONTACT US